CU/XLPE/AWA/LSF 0.6/1KV

Products

CU/XLP/AW/LSF 01 1X 16 R #D #N

Nexans ref. 13004989 - Country ref. 13004989

  • Packaging: Cut to length (m)
  • Conductor cross-section: 16 mm²

 

CU/XLP/AW/LSF 01 1X 25 C #D #N

Nexans ref. 13005200 - Country ref. 13005200

  • Packaging: Cut to length (m)
  • Conductor cross-section: 25 mm²

 

CU/XLP/AW/LSF 01 1X 35 C #D #N

Nexans ref. 13005202 - Country ref. 13005202

  • Packaging: Cut to length (m)
  • Conductor cross-section: 35 mm²

 

CU/XLP/AW/LSF 01 1X 50 C #D #N

Nexans ref. 13005204 - Country ref. 13005204

  • Packaging: Cut to length (m)
  • Conductor cross-section: 50 mm²

 

CU/XLP/AW/LSF 01 1X 70 C #D #N

Nexans ref. 13002334 - Country ref. 13002334

  • Packaging: Cut to length (m)
  • Conductor cross-section: 70 mm²

 

CU/XLP/AW/LSF 01 1X 95 C #D #N

Nexans ref. 13002153 - Country ref. 13002153

  • Packaging: Cut to length (m)
  • Conductor cross-section: 95 mm²

 

CU/XLP/AW/LSF 01 1X120 C #D #N

Nexans ref. 13002152 - Country ref. 13002152

  • Packaging: Cut to length (m)
  • Conductor cross-section: 120 mm²

 

CU/XLP/AW/LSF 01 1X150 C #D #N

Nexans ref. 13002190 - Country ref. 13002190

  • Packaging: Cut to length (m)
  • Conductor cross-section: 150 mm²

 

CU/XLP/AW/LSF 01 1X185 C #D #N

Nexans ref. 13000602 - Country ref. 13000602

  • Packaging: Cut to length (m)
  • Conductor cross-section: 185 mm²

 

CU/XLP/AW/LSF 01 1X240 C #D #N

Nexans ref. 13005213 - Country ref. 13005213

  • Packaging: Cut to length (m)
  • Conductor cross-section: 240 mm²

 

CU/XLP/AW/LSF 01 1X300 C #D #N

Nexans ref. 13005001 - Country ref. 13005001

  • Packaging: Cut to length (m)
  • Conductor cross-section: 300 mm²

 

CU/XLP/AW/LSF 01 1X400 C #D #N

Nexans ref. 13005693 - Country ref. 13005693

  • Packaging: Cut to length (m)
  • Conductor cross-section: 400 mm²

 

CU/XLP/AW/LSF 01 1X500 C #D #N

Nexans ref. 13005695 - Country ref. 13005695

  • Packaging: Cut to length (m)
  • Conductor cross-section: 500 mm²

 

Description

Description

Standards

  • International
    IEC 60332-1-2; IEC 60332-3-24; IEC 60502-1; IEC 60754-1; IEC 60754-2; IEC 61034
  • National
    BS 6724

Electric cable with copper conductor, XLPE insulation, LSF bedding, Aluminium wires armour (AWA) and LSF outer sheath

 

Application

safety cable, suitable for indoor and outdoor installation, in air and ground, where the cables should be flame retardant and halogen free

 

Core colour: Brown

On request other color could be available

 

Note: Mutli-core cables are with galvanized steel wires armour (SWA) with family designation: CU/XLPE/SWA/LSF 0.6/1KV

 

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Copper
Conductor flexibility
Stranded class 2
Insulation
XLPE (chemical)
Inner sheath
HFFR (polyolefin)
Armour type
Aluminium Wire
Outer sheath
HFFR (polyolefin)
Colour
Black
Lead free
Yes
Halogen free
Yes

Dimensional characteristics

Dimensional characteristics

Number of cores
1

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0,6/1 kV

Usage characteristics

Usage characteristics

Max. conductor temperature in service
90 °C
Short-circuit max. conductor temperature
250 °C

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close