- Company
- Markets
-
Products
- Products
- Building cables
- Outdoor/Industrial Non Armored Cables
- Outdoor/Industrial Armored Cables
- Earth Conductors
- Solar farms
- Safety Cables
- Power Distribution Aerial cables
- Power Transmission & Distribution Conductors OHL
- Power Distribution cables
-
MV Underground Armored cables
- Overview
- CU/XLPE/CTS/LSF/AWA/LSF 6.35/11KV
- CU/XLPE/CTS/PVC/SWA/PVC 12.7/22KV RED STRIPE
- CU/XLPE/CTS/PVC/AWA/PVC 6.35/11KV
- CU/XLPE/CTS/PVC/SWA/PVC 6.35/11KV
- CU/XLPE/CTS/LSF/SWA/LSF 6.35/11 KV
- CU/XLPE/CTS/PVC/SWA/PVC 19/33KV RED STRIPE
- CU/XLPE/CTS/PVC/AWA/PVC 19/33KV
- CU/XLPE/CTS/PVC/AWA/PVC 12.7/22KV RED STRIPE
- CU/XLPE/CTS/PVC/SWA/PVC 6.35/11KV RED STRIPE
- CU/XLPE/CTS/PVC/AWA/PVC 6.35/11KV RED STRIPE
- CU/XLPE/CTS/PVC/AWA/PVC 19/33 KV RED STRIPE
-
MV Underground Unarmored cables
- Overview
- NA2XS(F)2Y RM 6/10 KV
- CU/XLPE/CWS/PE 6.35/11KV - BS 7870-4.10
- A2XS(F)2Y 12/20KV - IEC
- NA2XS(F)2Y RM 18/30 kV
- AL/XLPE/CWS/PVC 12/20KV - DEH
- NA2XS(F)2Y RM 12/20 kV
- CU/XLPE/CWS/PE 6.35/11KV - TRIPLEX - BS 7870-4.10
- 2XSY 12/20 KV - IEC
- AL/XLPE/CWS/PE 6.35/11KV - TRIPLEX - BS 7870-4.10
- AL/XLPE/PVC 12/20KV - triplex - Underground - DEH
- A2XSY 12/20KV - IEC
- CU/XLPE/CWS/PVC 12/20KV 3-CORE -IEC
- AL/XLPE/AWS/PE 6.35/11KV - TRIPLEX - IEC
- AL/XLPE/CWS/WB/PE 19/33KV - BS 7870-4.10
- AL/XLPE/CWS/PE 19/33KV - BS 7870-4.10
- AL/XLPE/AWS/WB/PE 19/33KV
- AL/XLPE/CWS/PE/SC 19/33KV - BS 7870-4.10
- A2XSH 12/20KV - DEH
- AXCLIGHT TT 12kV
- AXCLIGHT TT E 36kV
- NA2XS(FL)2Y V RM 12/20 kV
- AXCLIGHT TT 24kV
- CU/XLPE/AWS/PE 6.35/11KV - TRIPLEX - IEC
- AL/XLPE/AL-PE/PE 12/20KV 3.0 - IEC
- NA2XS(F)2Y RM 12/20 kV - triplex
- MV Underground Unarmored cables
- NA2XS(F)2Y V RM 12/20 kV
- AXLJ TT 36 kV
- CU/XLPE/AWS/LSF 6.35/11KV - IEC
- NA2XS2Y RM 6/10 KV - Triplex
- Newsroom
- Tools & Resources
- Newsletter
- Search
- Contact us
- Compare
- Sign in
AL/XLPE/CWS/PE 6.35/11KV - BS 7870-4.20
AL/XLPE/CWS/PE 6.35/11KV - BS 7870-4.20
MV 3-core cable XLPE insulated. Rated voltage 6.35/11 KV (Um=12KV)
Read moreAL/XLP/PE 11 3X 70/60 C RD #D #R
Nexans ref. 13004871 - Country ref. 13004871
- Packaging: Cut to length (m)
- Conductor flexibility: Stranded class 2
- Conductor cross-section: 70 mm²
- Phase Conductor Cross Section: 70 mm²
- Nominal outer sheath thickness: 2.6 mm
- Nominal outer diameter: 48.0 mm
AL/XLP/PE 11 3X 70/60 U RD #D #R
Nexans ref. 13004944 - Country ref. 13004944
- Packaging: Cut to length (m)
- Conductor flexibility: Solid class 1
- Conductor cross-section: 70 mm²
- Phase Conductor Cross Section: 150 mm²
- Nominal outer sheath thickness: 2.6 mm
- Nominal outer diameter: 48.0 mm
AL/XLP/PE 11 3X150/60 C RD #D #R
Nexans ref. 13004793 - Country ref. 13004793
- Packaging: Cut to length (m)
- Conductor flexibility: Stranded class 2
- Conductor cross-section: 150 mm²
- Phase Conductor Cross Section: 150 mm²
- Nominal outer sheath thickness: 2.9 mm
- Nominal outer diameter: 59.0 mm
AL/XLP/PE 11 3X150/60 U RD #D #R
Nexans ref. 13004945 - Country ref. 13004945
- Packaging: Cut to length (m)
- Conductor flexibility: Solid class 1
- Conductor cross-section: 150 mm²
- Phase Conductor Cross Section: 150 mm²
- Nominal outer sheath thickness: 2.9 mm
- Nominal outer diameter: 59.0 mm
AL/XLP/PE 11 3X240/60 C RD #D #R
Nexans ref. 13004821 - Country ref. 13004821
- Packaging: Cut to length (m)
- Conductor flexibility: Stranded class 2
- Conductor cross-section: 240 mm²
- Phase Conductor Cross Section: 240 mm²
- Nominal outer sheath thickness: 3.2 mm
- Nominal outer diameter: 68.0 mm
AL/XLP/PE 11 3X240/60 U RD #D #R
Nexans ref. 13004946 - Country ref. 13004946
- Packaging: Cut to length (m)
- Conductor flexibility: Solid class 1
- Conductor cross-section: 240 mm²
- Phase Conductor Cross Section: 240 mm²
- Nominal outer sheath thickness: 3.2 mm
- Nominal outer diameter: 68.0 mm
AL/XLP/PE 11 3X300/60 C RD #D #R
Nexans ref. 13004943 - Country ref. 13004943
- Packaging: Cut to length (m)
- Conductor flexibility: Stranded class 2
- Conductor cross-section: 300 mm²
- Phase Conductor Cross Section: 300 mm²
- Nominal outer sheath thickness: 3.3 mm
- Nominal outer diameter: 78.0 mm
AL/XLP/PE 11 3X300/60 U RD #D #R
Nexans ref. 13004947 - Country ref. 13004947
- Packaging: Cut to length (m)
- Conductor flexibility: Solid class 1
- Conductor cross-section: 300 mm²
- Phase Conductor Cross Section: 300 mm²
- Nominal outer sheath thickness: 3.3 mm
- Nominal outer diameter: 78.0 mm
Description
Description
Standards
-
ProductBS 7870-4.20; IEC 60502-2
Application
Three core MV cable suitable for outdoor and indoor installation, in air, in grounds, and in cable ducts.
The cable is suitable for rated voltage 6/10KV (Um=12KV) according to the IEC standards.
Construction
The cable is consisted of stranded (class 2) Aluminium conductor, with water protection or solid (class 1) Aluminium conductor (SAC), conductor screen of semiconducting compound, XLPE insulation, insulation screen of semiconducting compound, three insulated cores are laid-up together and wrapped with semiconductive tape (-s), collective metallic screen copper wires and copper helix tape, PE outer sheath.
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania