CU/XLPE/CWS/PE 6.35/11KV - BS 7870-4.10

Products

CU/XLPE/CWS/PE 6.35/11kV 1X 70/35

Nexans ref. 13006126 - Country ref. 13006126

  • Packaging: Cut to length (m)
  • Conductor cross-section: 70 mm²

 

CU/XLPE/CWS/PE 6.35/11kV 1X 95/35

Nexans ref. 13006127 - Country ref. 13006127

  • Packaging: Cut to length (m)
  • Conductor cross-section: 95 mm²

 

CU/XLPE/CWS/PE 6.35/11kV 1X120/35

Nexans ref. 13006128 - Country ref. 13006128

  • Packaging: Cut to length (m)
  • Conductor cross-section: 120 mm²

 

CU/XLPE/CWS/PE 6.35/11kV 1X150/35

Nexans ref. 13006129 - Country ref. 13006129

  • Packaging: Cut to length (m)
  • Conductor cross-section: 150 mm²

 

CU/XLPE/CWS/PE 6.35/11kV 1X185/35

Nexans ref. 13006130 - Country ref. 13006130

  • Packaging: Cut to length (m)
  • Conductor cross-section: 185 mm²

 

CU/XLPE/CWS/PE 6.35/11kV 1X240/35

Nexans ref. 13006131 - Country ref. 13006131

  • Packaging: Cut to length (m)
  • Conductor cross-section: 240 mm²

 

CU/XLPE/CWS/PE 6.35/11kV 1X300/35

Nexans ref. 13006132 - Country ref. 13006132

  • Packaging: Cut to length (m)
  • Conductor cross-section: 300 mm²

 

CU/XLPE/CWS/PE 6.35/11kV 1X400/35

Nexans ref. 13002214 - Country ref. 13002214

  • Packaging: Cut to length (m)
  • Conductor cross-section: 400 mm²

 

CU/XLPE/CWS/PE 6.35/11kV 1X500/35

Nexans ref. 13005644 - Country ref. 13005644

  • Packaging: Cut to length (m)
  • Conductor cross-section: 500 mm²

 

CU/XLPE/CWS/PE 6.35/11kV 1X630/35

Nexans ref. 13006133 - Country ref. 13006133

  • Packaging: Cut to length (m)
  • Conductor cross-section: 630 mm²

 

Description

Description

Standards

  • Product
    BS 7870-4.10 ; IEC 60502-2

Application

Single core MV cable suitable for outdoor and indoor installation, in air, in grounds, and in cable ducts.

The cable is suitable for rated voltage 6/10KV (Um=12KV) according to the IEC standards.

Construction

The single core MV cable is consisted of stranded (class 2) copper conductor, conductor screen of semiconducting compound, XLPE insulation, insulation screen of semiconducting compound, copper wires metallic screen, PE outer sheath.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Copper
Conductor flexibility
Stranded class 2
Material of the inner semi-conductor
Semi-conducting compound
Insulation
XLPE (chemical)
Material of the external semi-conductor
Semi-conducting compound
Screen
Copper wire
Outer sheath
PE
Halogen free
Yes
Lead free
Yes

Dimensional characteristics

Dimensional characteristics

Number of cores
1
Screen section
35 mm²

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
6.35 / 11 kV

Usage characteristics

Usage characteristics

Flame retardant
No

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close