AL/XLPE/CWS/PE 6.35/11KV - TRIPLEX - BS 7870-4.10

Products

AL/XLPE/CWS/PE 6.35/11KV 3X1X 70/35 C

Nexans ref. 13006120 - Country ref. 13006120

  • Packaging: Cut to length (m)
  • Conductor flexibility: Stranded class 2
  • Conductor cross-section: 70 mm²
  • Phase Conductor Cross Section: 70 mm²
  • Screen section: 35 mm²
  • Nominal outer sheath thickness: 1.7 mm
  • Nominal outer diameter: 55.0 mm

 

AL/XLPE/CWS/PE 6.35/11KV 3X1X 95/35 C

Nexans ref. 13002544 - Country ref. 13002544

  • Packaging: Cut to length (m)
  • Conductor flexibility: Stranded class 2
  • Conductor cross-section: 95 mm²
  • Phase Conductor Cross Section: 95 mm²
  • Screen section: 35 mm²
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 58.0 mm

 

AL/XLPE/CWS/PE 6.35/11KV 3X1X120/35 C

Nexans ref. 13006121 - Country ref. 13006121

  • Packaging: Cut to length (m)
  • Conductor flexibility: Stranded class 2
  • Conductor cross-section: 120 mm²
  • Phase Conductor Cross Section: 120 mm²
  • Screen section: 35 mm²
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 63.0 mm

 

AL/XLPE/CWS/PE 6.35/11KV 3X1X150/35 C

Nexans ref. 13006122 - Country ref. 13006122

  • Packaging: Cut to length (m)
  • Conductor flexibility: Stranded class 2
  • Conductor cross-section: 150 mm²
  • Phase Conductor Cross Section: 150 mm²
  • Screen section: 35 mm²
  • Nominal outer sheath thickness: 1.9 mm
  • Nominal outer diameter: 66.0 mm

 

AL/XLPE/CWS/PE 6.35/11KV 3X1X185/35 C

Nexans ref. 13002574 - Country ref. 13002574

  • Packaging: Cut to length (m)
  • Conductor flexibility: Stranded class 2
  • Conductor cross-section: 185 mm²
  • Phase Conductor Cross Section: 185 mm²
  • Screen section: 35 mm²
  • Nominal outer sheath thickness: 1.9 mm
  • Nominal outer diameter: 71.0 mm

 

AL/XLPE/CWS/PE 6.35/11KV 3X1X185/70 C

Nexans ref. 13004053 - Country ref. 13004053

  • Packaging: Cut to length (m)
  • Conductor flexibility: Stranded class 2
  • Conductor cross-section: 185 mm²
  • Phase Conductor Cross Section: 185 mm²
  • Screen section: 70 mm²
  • Nominal outer sheath thickness: 1.9 mm
  • Nominal outer diameter: 71.0 mm

 

AL/XLPE/CWS/PE 6.35/11KV 3X1X185/70 U

Nexans ref. 13003509 - Country ref. 13003509

  • Packaging: Cut to length (m)
  • Conductor flexibility: Solid class 1
  • Conductor cross-section: 185 mm²
  • Phase Conductor Cross Section: 185 mm²
  • Screen section: 70 mm²
  • Nominal outer sheath thickness: 1.9 mm
  • Nominal outer diameter: 71.0 mm

 

AL/XLPE/CWS/PE 6.35/11KV 3X1X240/35 C

Nexans ref. 13006123 - Country ref. 13006123

  • Packaging: Cut to length (m)
  • Conductor flexibility: Stranded class 2
  • Conductor cross-section: 240 mm²
  • Phase Conductor Cross Section: 240 mm²
  • Screen section: 35 mm²
  • Nominal outer sheath thickness: 2.0 mm
  • Nominal outer diameter: 76.0 mm

 

AL/XLPE/CWS/PE 6.35/11KV 3X1X300/35 C

Nexans ref. 13002546 - Country ref. 13002546

  • Packaging: Cut to length (m)
  • Conductor flexibility: Stranded class 2
  • Conductor cross-section: 300 mm²
  • Phase Conductor Cross Section: 300 mm²
  • Screen section: 35 mm²
  • Nominal outer sheath thickness: 2.1 mm
  • Nominal outer diameter: 79.0 mm

 

AL/XLPE/CWS/PE 6.35/11KV 3X1X300/50 C

Nexans ref. 13005928 - Country ref. 13005928

  • Packaging: Cut to length (m)
  • Conductor flexibility: Stranded class 2
  • Conductor cross-section: 300 mm²
  • Phase Conductor Cross Section: 300 mm²
  • Screen section: 50 mm²
  • Nominal outer sheath thickness: 2.1 mm
  • Nominal outer diameter: 79.0 mm

 

AL/XLPE/CWS/PE 6.35/11KV 3X1X300/50 U

Nexans ref. 13005940 - Country ref. 13005940

  • Packaging: Cut to length (m)
  • Conductor flexibility: Solid class 1
  • Conductor cross-section: 300 mm²
  • Phase Conductor Cross Section: 300 mm²
  • Screen section: 50 mm²
  • Nominal outer sheath thickness: 2.1 mm
  • Nominal outer diameter: 75.0 mm

 

AL/XLPE/CWS/PE 6.35/11KV 3X1X300/70 C

Nexans ref. 13005939 - Country ref. 13005939

  • Packaging: Cut to length (m)
  • Conductor flexibility: Stranded class 2
  • Conductor cross-section: 300 mm²
  • Phase Conductor Cross Section: 300 mm²
  • Screen section: 70 mm²
  • Nominal outer sheath thickness: 2.1 mm
  • Nominal outer diameter: 79.0 mm

 

AL/XLPE/CWS/PE 6.35/11KV 3X1X300/70 U

Nexans ref. 13005941 - Country ref. 13005941

  • Packaging: Cut to length (m)
  • Conductor flexibility: Solid class 1
  • Conductor cross-section: 300 mm²
  • Phase Conductor Cross Section: 300 mm²
  • Screen section: 70 mm²
  • Nominal outer sheath thickness: 2.1 mm
  • Nominal outer diameter: 75.0 mm

 

AL/XLPE/CWS/PE 6.35/11KV 3X1X400/50 C

Nexans ref. 13004464 - Country ref. 13004464

  • Packaging: Cut to length (m)
  • Conductor flexibility: Stranded class 2
  • Conductor cross-section: 400 mm²
  • Phase Conductor Cross Section: 400 mm²
  • Screen section: 50 mm²
  • Nominal outer sheath thickness: 2.2 mm
  • Nominal outer diameter: 85.0 mm

 

AL/XLPE/CWS/PE 6.35/11KV 3X1X400/70 C

Nexans ref. 13006233 - Country ref. 13006233

  • Packaging: Cut to length (m)
  • Conductor flexibility: Stranded class 2
  • Conductor cross-section: 400 mm²
  • Phase Conductor Cross Section: 400 mm²
  • Screen section: 70 mm²
  • Nominal outer sheath thickness: 2.2 mm
  • Nominal outer diameter: 85.0 mm

 

Description

Description

Standards

  • International
    IEC 60502-2
  • National
    BS 7870-4.10 

Electric cable with stranded (class 2), with or without water protection, or solid (class 1) Aluminium conductor, conductor screen of semiconducting compound, XLPE insulation, insulation screen of semiconducting compound, copper wires metallic screen, PE outer sheath. Three single core cables are laid-up together in triplex formation.

 

Application

in grounds, outdoors, indoors and in cable ducts 

The cable is suitable for rated voltage 6/10KV (Um=12KV) according to the IEC standards.

 

Note:

on request the cables are available with copper helix tape above the copper wires metallic screen and/or longitudinal water protection of metallic screen. Other cross section of metallic screen are available on request.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Aluminum
Conductor shape
Circular
Material of the inner semi-conductor
Semi-conducting compound
Insulation
XLPE
Material of the external semi-conductor
Semi-conducting compound
Screen
Copper wire
Outer sheath
MDPE
Halogen free
Yes

Dimensional characteristics

Dimensional characteristics

Number of cores
3
Nominal insulation thickness
3.4 mm

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
6.35 / 11 kV

Usage characteristics

Usage characteristics

Flame retardant
No

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close