U-1000 R2V single core

Products

R2V 1X 16 R #D

Nexans ref. 13003222 - Country ref. 13003222

  • Packaging: Cut to length (m)
  • Conductor cross-section: 16 mm²
  • Phase Conductor Cross Section: 16 mm²
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.4 mm
  • Nominal outer diameter: 9.2 mm
  • Approximate weight: 190 kg/km
  • Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
  • Permissible current rating when buried: 107 A
  • Permissible current rating in open air: 113 A
  • Voltage drop, 3 conductors: 2.1 V/A.km

 

R2V 1X 25 C #D

Nexans ref. 13000311 - Country ref. 13000311

  • Packaging: Cut to length (m)
  • Conductor cross-section: 25 mm²
  • Phase Conductor Cross Section: 25 mm²
  • Nominal insulation thickness: 0.9 mm
  • Nominal outer sheath thickness: 1.4 mm
  • Nominal outer diameter: 10.5 mm
  • Approximate weight: 270 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
  • Permissible current rating when buried: 138 A
  • Permissible current rating in open air: 144 A
  • Voltage drop, 3 conductors: 1.4 V/A.km

 

R2V 1X 35 C #D

Nexans ref. 13000312 - Country ref. 13000312

  • Packaging: Cut to length (m)
  • Conductor cross-section: 35 mm²
  • Phase Conductor Cross Section: 35 mm²
  • Nominal insulation thickness: 0.9 mm
  • Nominal outer sheath thickness: 1.4 mm
  • Nominal outer diameter: 11.5 mm
  • Approximate weight: 370 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
  • Permissible current rating when buried: 169 A
  • Permissible current rating in open air: 174 A
  • Voltage drop, 3 conductors: 1.0 V/A.km

 

R2V 1X 50 C #D

Nexans ref. 13000313 - Country ref. 13000313

  • Packaging: Cut to length (m)
  • Conductor cross-section: 50 mm²
  • Phase Conductor Cross Section: 50 mm²
  • Nominal insulation thickness: 1.0 mm
  • Nominal outer sheath thickness: 1.4 mm
  • Nominal outer diameter: 12.5 mm
  • Approximate weight: 490 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
  • Permissible current rating when buried: 206 A
  • Permissible current rating in open air: 207 A
  • Voltage drop, 3 conductors: 0.78 V/A.km

 

R2V 1X 70 C #D

Nexans ref. 13000314 - Country ref. 13000314

  • Packaging: Cut to length (m)
  • Conductor cross-section: 70 mm²
  • Phase Conductor Cross Section: 70 mm²
  • Nominal insulation thickness: 1.1 mm
  • Nominal outer sheath thickness: 1.4 mm
  • Nominal outer diameter: 14.5 mm
  • Approximate weight: 685 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
  • Permissible current rating when buried: 254 A
  • Permissible current rating in open air: 268 A
  • Voltage drop, 3 conductors: 0.56 V/A.km

 

R2V 1X 95 C #D

Nexans ref. 13000315 - Country ref. 13000315

  • Packaging: Cut to length (m)
  • Conductor cross-section: 95 mm²
  • Phase Conductor Cross Section: 95 mm²
  • Nominal insulation thickness: 1.1 mm
  • Nominal outer sheath thickness: 1.5 mm
  • Nominal outer diameter: 16.5 mm
  • Approximate weight: 930 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.193 Ohm/km
  • Permissible current rating when buried: 301 A
  • Permissible current rating in open air: 328 A
  • Voltage drop, 3 conductors: 0.43 V/A.km

 

R2V 1X120 C #D

Nexans ref. 13000316 - Country ref. 13000316

  • Packaging: Cut to length (m)
  • Conductor cross-section: 120 mm²
  • Phase Conductor Cross Section: 120 mm²
  • Nominal insulation thickness: 1.2 mm
  • Nominal outer sheath thickness: 1.5 mm
  • Nominal outer diameter: 18.0 mm
  • Approximate weight: 1170 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.153 Ohm/km
  • Permissible current rating when buried: 343 A
  • Permissible current rating in open air: 382 A
  • Voltage drop, 3 conductors: 0.36 V/A.km

 

R2V 1X150 C #D

Nexans ref. 13000317 - Country ref. 13000317

  • Packaging: Cut to length (m)
  • Conductor cross-section: 150 mm²
  • Phase Conductor Cross Section: 150 mm²
  • Nominal insulation thickness: 1.4 mm
  • Nominal outer sheath thickness: 1.6 mm
  • Nominal outer diameter: 20.0 mm
  • Approximate weight: 1430 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.124 Ohm/km
  • Permissible current rating when buried: 387 A
  • Permissible current rating in open air: 441 A
  • Voltage drop, 3 conductors: 0.31 V/A.km

 

R2V 1X185 C #D

Nexans ref. 13000319 - Country ref. 13000319

  • Packaging: Cut to length (m)
  • Conductor cross-section: 185 mm²
  • Phase Conductor Cross Section: 185 mm²
  • Nominal insulation thickness: 1.6 mm
  • Nominal outer sheath thickness: 1.6 mm
  • Nominal outer diameter: 22.0 mm
  • Approximate weight: 1785 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.099 Ohm/km
  • Permissible current rating when buried: 434 A
  • Permissible current rating in open air: 506 A
  • Voltage drop, 3 conductors: 0.26 V/A.km

 

R2V 1X240 C #D

Nexans ref. 13000320 - Country ref. 13000320

  • Packaging: Cut to length (m)
  • Conductor cross-section: 240 mm²
  • Phase Conductor Cross Section: 240 mm²
  • Nominal insulation thickness: 1.7 mm
  • Nominal outer sheath thickness: 1.7 mm
  • Nominal outer diameter: 24.6 mm
  • Approximate weight: 2290 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.075 Ohm/km
  • Permissible current rating when buried: 501 A
  • Permissible current rating in open air: 599 A
  • Voltage drop, 3 conductors: 0.22 V/A.km

 

R2V 1X300 C #D

Nexans ref. 13001050 - Country ref. 13001050

  • Packaging: Cut to length (m)
  • Conductor cross-section: 300 mm²
  • Phase Conductor Cross Section: 300 mm²
  • Nominal insulation thickness: 1.8 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 27.5 mm
  • Approximate weight: 2900 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.06 Ohm/km
  • Permissible current rating when buried: 565 A
  • Permissible current rating in open air: 693 A
  • Voltage drop, 3 conductors: 0.19 V/A.km

 

R2V 1X400 C #D

Nexans ref. 13000321 - Country ref. 13000321

  • Packaging: Cut to length (m)
  • Conductor cross-section: 400 mm²
  • Phase Conductor Cross Section: 400 mm²
  • Nominal insulation thickness: 2.0 mm
  • Nominal outer sheath thickness: 1.9 mm
  • Nominal outer diameter: 30.4 mm
  • Approximate weight: 3715 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.047 Ohm/km
  • Permissible current rating when buried: 662 A
  • Permissible current rating in open air: 825 A
  • Voltage drop, 3 conductors: 0.17 V/A.km

 

R2V 1X500 C #D

Nexans ref. 13005119 - Country ref. 13005119

  • Packaging: Cut to length (m)
  • Conductor cross-section: 500 mm²
  • Phase Conductor Cross Section: 500 mm²
  • Nominal insulation thickness: 2.2 mm
  • Nominal outer sheath thickness: 2.0 mm
  • Nominal outer diameter: 34.0 mm
  • Approximate weight: 4840 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.037 Ohm/km
  • Permissible current rating when buried: 750 A
  • Permissible current rating in open air: 946 A
  • Voltage drop, 3 conductors: 0.15 V/A.km

 

Description

Description

Standards

  • International
    IEC 60332-1; IEC 60502-1
  • National
    XP C 32-321

Electric cable with stranded copper conductor, XLPE insulation and PVC outer sheath.

 

Application

for fixed installations in dry or wet places. Installation in open air or in ground with protection.

 

Cable construction

1. copper conductor

2. XLPE insulation

3. PVC outer sheath

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Copper
Conductor shape
Circular
Type of conductor
Class 2
Conductor flexibility
Stranded class 2
Insulation
XLPE
Outer sheath
PVC
Sheath colour
Black
Lead free
Yes

Dimensional characteristics

Dimensional characteristics

Number of cores
1

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0.6/ 1 (1.2) kV

Mechanical characteristics

Mechanical characteristics

Cable flexibility
Rigid
Mechanical resistance to impacts
Good

Usage characteristics

Usage characteristics

Max. conductor temperature in service
90 °C
Short-circuit max. conductor temperature
250 °C
Weather resistance
Yes

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close