CU/XLPE/CTS/PVC/SWA/PVC 6.35/11KV RED STRIPE

Products

CU/XLPE/SWA/PVC 11KV 3X 25

Nexans ref. 13006094 - Country ref. 13006094

  • Packaging: Cut to length (m)
  • Phase Conductor Cross Section: 25 mm²
  • Inner sheath thickness: 1.3 mm
  • Nominal outer sheath thickness: 2.4 mm

 

CU/XLPE/SWA/PVC 11KV 3X 35

Nexans ref. 13001062 - Country ref. 13001062

  • Packaging: Cut to length (m)
  • Phase Conductor Cross Section: 35 mm²
  • Inner sheath thickness: 1.3 mm
  • Nominal outer sheath thickness: 2.5 mm

 

CU/XLPE/SWA/PVC 11KV 3X 50

Nexans ref. 13000091 - Country ref. 13000091

  • Packaging: Cut to length (m)
  • Phase Conductor Cross Section: 50 mm²
  • Inner sheath thickness: 1.4 mm
  • Nominal outer sheath thickness: 2.6 mm

 

CU/XLPE/SWA/PVC 11KV 3X 70

Nexans ref. 13000092 - Country ref. 13000092

  • Packaging: Cut to length (m)
  • Phase Conductor Cross Section: 70 mm²
  • Inner sheath thickness: 1.4 mm
  • Nominal outer sheath thickness: 2.7 mm

 

CU/XLPE/SWA/PVC 11KV 3X 95

Nexans ref. 13003472 - Country ref. 13003472

  • Packaging: Cut to length (m)
  • Phase Conductor Cross Section: 95 mm²
  • Inner sheath thickness: 1.5 mm
  • Nominal outer sheath thickness: 2.8 mm

 

CU/XLPE/SWA/PVC 11KV 3X120

Nexans ref. 13004323 - Country ref. 13004323

  • Packaging: Cut to length (m)
  • Phase Conductor Cross Section: 120 mm²
  • Inner sheath thickness: 1.6 mm
  • Nominal outer sheath thickness: 3.0 mm

 

CU/XLPE/SWA/PVC 11KV 3X150

Nexans ref. 13000095 - Country ref. 13000095

  • Packaging: Cut to length (m)
  • Phase Conductor Cross Section: 150 mm²
  • Inner sheath thickness: 1.6 mm
  • Nominal outer sheath thickness: 3.1 mm

 

CU/XLPE/SWA/PVC 11KV 3X185

Nexans ref. 13000096 - Country ref. 13000096

  • Packaging: Cut to length (m)
  • Phase Conductor Cross Section: 185 mm²
  • Inner sheath thickness: 1.7 mm
  • Nominal outer sheath thickness: 3.2 mm

 

CU/XLPE/SWA/PVC 11KV 3X240

Nexans ref. 13001069 - Country ref. 13001069

  • Packaging: Cut to length (m)
  • Phase Conductor Cross Section: 240 mm²
  • Inner sheath thickness: 1.8 mm
  • Nominal outer sheath thickness: 3.4 mm

 

CU/XLPE/SWA/PVC 11KV 3X300

Nexans ref. 13004154 - Country ref. 13004154

  • Packaging: Cut to length (m)
  • Phase Conductor Cross Section: 300 mm²
  • Inner sheath thickness: 1.9 mm
  • Nominal outer sheath thickness: 3.6 mm

 

CU/XLPE/SWA/PVC 11KV 3X400

Nexans ref. 13006095 - Country ref. 13006095

  • Packaging: Cut to length (m)
  • Phase Conductor Cross Section: 400 mm²
  • Inner sheath thickness: 2.0 mm
  • Nominal outer sheath thickness: 3.8 mm

 

Description

Description

Standards

  • International
    IEC 60332-1; IEC 60332-3-24
  • National
    SANS 1339

Electric cable with copper conductors, semiconductive conductor screen, XLPE insulation, semiconductive insulation screen, copper tape metallic screen of each core, PVC bedding, galvanized steel wires armour (SWA) and PVC outer sheath, black with red stripe.

 

Application

for energy networks where mechanical stresses are expected. Suitable for underground installation or in ducts

 

The cable is suitable for rated voltage 6/10KV according to IEC 60502-2 

 

Design

1. copper conductor

2. semiconductive conductor screen

3. XLPE insulation

4. semiconductive insulation screen

5. semiconductive tape

6. copper tape metallic screen

6. PVC bedding

7. galvanized steel wires armour

8. PVC outer sheath

 

Single core xables are with Aluminium wires armour (AWA) with designation: CU/XLPE/CTS/PVC/AWA/PVC 6.35/11KV

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Copper
Conductor shape
Circular
Conductor flexibility
Stranded class 2
Material of the inner semi-conductor
Semi-conducting compound
Insulation
XLPE
Material of the external semi-conductor
Extruded strippable
Screen
Copper tape
Inner sheath
PVC
Armour type
Galvanized steel wires
Outer sheath
PVC
Colour
Black
Lead free
Yes

Dimensional characteristics

Dimensional characteristics

Number of cores
3
Nominal insulation thickness
3.4 mm
Screen thickness
0.1 µm

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
6.35 / 11 kV

Usage characteristics

Usage characteristics

Max. conductor temperature in service
90 °C
Short-circuit max. conductor temperature
250 °C
Flame retardant
IEC 60332-1
Fire retardant
IEC 60332-3-24

Resources

Resources

Selling & delivery Information

the cable is available with flame retardant reduced halogen emission PVC sheath, black with blue stripe (LHFR) or with flame retardant, low smoke, zero halogen sheath, black with white stripe (NHLSFR)

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close