- Company
- Markets
-
Products
- Products
- Building cables
- Outdoor/Industrial Non Armored Cables
- Outdoor/Industrial Armored Cables
- Earth Conductors
- Solar farms
- Safety Cables
- Power Distribution Aerial cables
- Power Transmission & Distribution Conductors OHL
- Power Distribution cables
-
MV Underground Armored cables
- Overview
- CU/XLPE/CTS/LSF/AWA/LSF 6.35/11KV
- CU/XLPE/CTS/PVC/SWA/PVC 12.7/22KV RED STRIPE
- CU/XLPE/CTS/PVC/AWA/PVC 6.35/11KV
- CU/XLPE/CTS/PVC/SWA/PVC 6.35/11KV
- CU/XLPE/CTS/LSF/SWA/LSF 6.35/11 KV
- CU/XLPE/CTS/PVC/SWA/PVC 19/33KV RED STRIPE
- CU/XLPE/CTS/PVC/AWA/PVC 19/33KV
- CU/XLPE/CTS/PVC/AWA/PVC 12.7/22KV RED STRIPE
- CU/XLPE/CTS/PVC/SWA/PVC 6.35/11KV RED STRIPE
- CU/XLPE/CTS/PVC/AWA/PVC 6.35/11KV RED STRIPE
- CU/XLPE/CTS/PVC/AWA/PVC 19/33 KV RED STRIPE
-
MV Underground Unarmored cables
- Overview
- NA2XS(F)2Y RM 6/10 KV
- CU/XLPE/CWS/PE 6.35/11KV - BS 7870-4.10
- A2XS(F)2Y 12/20KV - IEC
- NA2XS(F)2Y RM 18/30 kV
- AL/XLPE/CWS/PVC 12/20KV - DEH
- NA2XS(F)2Y RM 12/20 kV
- CU/XLPE/CWS/PE 6.35/11KV - TRIPLEX - BS 7870-4.10
- 2XSY 12/20 KV - IEC
- AL/XLPE/CWS/PE 6.35/11KV - TRIPLEX - BS 7870-4.10
- AL/XLPE/PVC 12/20KV - triplex - Underground - DEH
- A2XSY 12/20KV - IEC
- CU/XLPE/CWS/PVC 12/20KV 3-CORE -IEC
- AL/XLPE/AWS/PE 6.35/11KV - TRIPLEX - IEC
- AL/XLPE/CWS/WB/PE 19/33KV - BS 7870-4.10
- AL/XLPE/CWS/PE 19/33KV - BS 7870-4.10
- AL/XLPE/AWS/WB/PE 19/33KV
- AL/XLPE/CWS/PE/SC 19/33KV - BS 7870-4.10
- A2XSH 12/20KV - DEH
- AXCLIGHT TT 12kV
- AXCLIGHT TT E 36kV
- NA2XS(FL)2Y V RM 12/20 kV
- AXCLIGHT TT 24kV
- CU/XLPE/AWS/PE 6.35/11KV - TRIPLEX - IEC
- AL/XLPE/AL-PE/PE 12/20KV 3.0 - IEC
- NA2XS(F)2Y RM 12/20 kV - triplex
- AL/XLPE/CWS/PE 6.35/11KV - BS 7870-4.20
- NA2XS(F)2Y V RM 12/20 kV
- AXLJ TT 36 kV
- CU/XLPE/AWS/LSF 6.35/11KV - IEC
- NA2XS2Y RM 6/10 KV - Triplex
- Telecom and Data
- Newsroom
- Tools & Resources
- Newsletter
- Search
- Contact us
- Compare
- Sign in
A05VV-U, A05VV-R
A05VV-U, A05VV-R
Cable for fixed installation with insullation and outer sheath of PVC. Rated voltage 300/500 V
Read moreA05VVR 2X 6 #C
Nexans ref. 13002920 - Country ref. 13002920
- Packaging: Coil (m)
- Number of cores: 2
- Conductor cross-section: 6 mm²
- Phase Conductor Cross Section: 6 mm²
- Ground conductor cross-section: - mm²
- Nominal insulation thickness: 0.8 mm
- Nominal outer sheath thickness: 1.2 mm
A05VVR 2X 6 #D
Nexans ref. 13002921 - Country ref. 13002921
- Packaging: Coil (m)
- Number of cores: 2
- Conductor cross-section: 6 mm²
- Phase Conductor Cross Section: 6 mm²
- Ground conductor cross-section: - mm²
- Nominal insulation thickness: 0.8 mm
- Nominal outer sheath thickness: 1.2 mm
A05VVR 2X10 #C
Nexans ref. 13001146 - Country ref. 13001146
- Packaging: Coil (m)
- Number of cores: 2
- Conductor cross-section: 10 mm²
- Phase Conductor Cross Section: 10 mm²
- Ground conductor cross-section: - mm²
- Nominal insulation thickness: 1.0 mm
- Nominal outer sheath thickness: 1.4 mm
A05VVR 2X10 #C
Nexans ref. 13000820 - Country ref. 13000820
- Packaging: Coil (m)
- Number of cores: 2
- Conductor cross-section: 10 mm²
- Phase Conductor Cross Section: 10 mm²
- Ground conductor cross-section: - mm²
- Nominal insulation thickness: 1.0 mm
- Nominal outer sheath thickness: 1.4 mm
A05VVR 2X10 #D
Nexans ref. 13001162 - Country ref. 13001162
- Packaging: Cut to length (m)
- Number of cores: 2
- Conductor cross-section: 10 mm²
- Phase Conductor Cross Section: 10 mm²
- Ground conductor cross-section: - mm²
- Nominal insulation thickness: 1.0 mm
- Nominal outer sheath thickness: 1.4 mm
A05VVR 2X16 #C
Nexans ref. 13001163 - Country ref. 13001163
- Packaging: Coil (m)
- Number of cores: 2
- Conductor cross-section: 16 mm²
- Phase Conductor Cross Section: 16 mm²
- Ground conductor cross-section: - mm²
- Nominal insulation thickness: 1.0 mm
- Nominal outer sheath thickness: 1.4 mm
A05VVR 2X16 #C
Nexans ref. 13000676 - Country ref. 13000676
- Packaging: Coil (m)
- Number of cores: 2
- Conductor cross-section: 16 mm²
- Phase Conductor Cross Section: 16 mm²
- Ground conductor cross-section: - mm²
- Nominal insulation thickness: 1.0 mm
- Nominal outer sheath thickness: 1.4 mm
A05VVR 2X16 #D
Nexans ref. 13005084 - Country ref. 13005084
- Packaging: Coil (m)
- Number of cores: 2
- Conductor cross-section: 16 mm²
- Phase Conductor Cross Section: 16 mm²
- Ground conductor cross-section: - mm²
- Nominal insulation thickness: 1.0 mm
- Nominal outer sheath thickness: 1.4 mm
A05VVR 3G 6 #C
Nexans ref. 13002922 - Country ref. 13002922
- Packaging: Coil (m)
- Number of cores: 3
- Conductor cross-section: 6 mm²
- Phase Conductor Cross Section: 6 mm²
- Ground conductor cross-section: 6 mm²
- Nominal insulation thickness: 0.8 mm
- Nominal outer sheath thickness: 1.4 mm
A05VVR 3G 6 #C/SL
Nexans ref. 13004971 - Country ref. 13004971
- Packaging: Coil (m)
- Number of cores: 3
- Conductor cross-section: 6 mm²
- Phase Conductor Cross Section: 6 mm²
- Ground conductor cross-section: 6 mm²
- Nominal insulation thickness: 0.8 mm
- Nominal outer sheath thickness: 1.4 mm
A05VVR 3G 6 #D
Nexans ref. 13002923 - Country ref. 13002923
- Packaging: Coil (m)
- Number of cores: 3
- Conductor cross-section: 6 mm²
- Phase Conductor Cross Section: 6 mm²
- Ground conductor cross-section: 6 mm²
- Nominal insulation thickness: 0.8 mm
- Nominal outer sheath thickness: 1.4 mm
A05VVR 3G10 #C
Nexans ref. 13001148 - Country ref. 13001148
- Packaging: Coil (m)
- Number of cores: 3
- Conductor cross-section: 10 mm²
- Phase Conductor Cross Section: 10 mm²
- Ground conductor cross-section: 10 mm²
- Nominal insulation thickness: 1.0 mm
- Nominal outer sheath thickness: 1.4 mm
A05VVR 3G10 #C
Nexans ref. 13000008 - Country ref. 13000008
- Packaging: Coil (m)
- Number of cores: 3
- Conductor cross-section: 10 mm²
- Phase Conductor Cross Section: 10 mm²
- Ground conductor cross-section: 10 mm²
- Nominal insulation thickness: 1.0 mm
- Nominal outer sheath thickness: 1.4 mm
A05VVR 3G10 #C/SL
Nexans ref. 13005004 - Country ref. 13005004
- Packaging: Coil (m)
- Number of cores: 3
- Conductor cross-section: 10 mm²
- Phase Conductor Cross Section: 10 mm²
- Ground conductor cross-section: 10 mm²
- Nominal insulation thickness: 1.0 mm
- Nominal outer sheath thickness: 1.4 mm
A05VVR 3G10 #D
Nexans ref. 13001097 - Country ref. 13001097
- Packaging: Cut to length (m)
- Number of cores: 3
- Conductor cross-section: 10 mm²
- Phase Conductor Cross Section: 10 mm²
- Ground conductor cross-section: 10 mm²
- Nominal insulation thickness: 1.0 mm
- Nominal outer sheath thickness: 1.4 mm
A05VVR 3G10+1.5 #C
Nexans ref. 13001149 - Country ref. 13001149
- Packaging: Coil (m)
- Number of cores: 3
- Conductor cross-section: 10 mm²
- Phase Conductor Cross Section: 10 mm²
- Ground conductor cross-section: 10 mm²
- Nominal insulation thickness: 1.0 mm
- Nominal outer sheath thickness: 1.4 mm
A05VVR 3G10+1.5 #C
Nexans ref. 13000009 - Country ref. 13000009
- Packaging: Coil (m)
- Number of cores: 3
- Conductor cross-section: 10 mm²
- Phase Conductor Cross Section: 10 mm²
- Ground conductor cross-section: 10 mm²
- Nominal insulation thickness: 1.0 mm
- Nominal outer sheath thickness: 1.4 mm
A05VVR 3G10+1.5 #D
Nexans ref. 13001098 - Country ref. 13001098
- Packaging: Cut to length (m)
- Number of cores: 3
- Conductor cross-section: 10 mm²
- Phase Conductor Cross Section: 10 mm²
- Ground conductor cross-section: 10 mm²
- Nominal insulation thickness: 1.0 mm
- Nominal outer sheath thickness: 1.4 mm
A05VVR 3G16 #C
Nexans ref. 13001099 - Country ref. 13001099
- Packaging: Coil (m)
- Number of cores: 3
- Conductor cross-section: 16 mm²
- Phase Conductor Cross Section: 16 mm²
- Ground conductor cross-section: 16 mm²
- Nominal insulation thickness: 1.0 mm
- Nominal outer sheath thickness: 1.4 mm
A05VVR 3G16 #D
Nexans ref. 13001150 - Country ref. 13001150
- Packaging: Cut to length (m)
- Number of cores: 3
- Conductor cross-section: 16 mm²
- Phase Conductor Cross Section: 16 mm²
- Ground conductor cross-section: 16 mm²
- Nominal insulation thickness: 1.0 mm
- Nominal outer sheath thickness: 1.4 mm
A05VVR 3G16 #D
Nexans ref. 13000627 - Country ref. 13000627
- Packaging: Coil (m)
- Number of cores: 3
- Conductor cross-section: 16 mm²
- Phase Conductor Cross Section: 16 mm²
- Ground conductor cross-section: 16 mm²
- Nominal insulation thickness: 1.0 mm
- Nominal outer sheath thickness: 1.4 mm
A05VVR 4G 6 #C
Nexans ref. 13000822 - Country ref. 13000822
- Packaging: Coil (m)
- Number of cores: 4
- Conductor cross-section: 6 mm²
- Phase Conductor Cross Section: 6 mm²
- Ground conductor cross-section: 6 mm²
- Nominal insulation thickness: 0.8 mm
- Nominal outer sheath thickness: 1.4 mm
A05VVR 4G 6 #C
Nexans ref. 13001151 - Country ref. 13001151
- Packaging: Coil (m)
- Number of cores: 4
- Conductor cross-section: 6 mm²
- Phase Conductor Cross Section: 6 mm²
- Ground conductor cross-section: 6 mm²
- Nominal insulation thickness: 0.8 mm
- Nominal outer sheath thickness: 1.4 mm
A05VVR 4G 6 #D
Nexans ref. 13002924 - Country ref. 13002924
- Packaging: Coil (m)
- Number of cores: 4
- Conductor cross-section: 6 mm²
- Phase Conductor Cross Section: 6 mm²
- Ground conductor cross-section: 6 mm²
- Nominal insulation thickness: 0.8 mm
- Nominal outer sheath thickness: 1.4 mm
A05VVR 4G10 #C
Nexans ref. 13001152 - Country ref. 13001152
- Packaging: Coil (m)
- Number of cores: 4
- Conductor cross-section: 10 mm²
- Phase Conductor Cross Section: 10 mm²
- Ground conductor cross-section: 10 mm²
- Nominal insulation thickness: 1.0 mm
- Nominal outer sheath thickness: 1.4 mm
A05VVR 4G10 #C
Nexans ref. 13000677 - Country ref. 13000677
- Packaging: Coil (m)
- Number of cores: 4
- Conductor cross-section: 10 mm²
- Phase Conductor Cross Section: 10 mm²
- Ground conductor cross-section: 10 mm²
- Nominal insulation thickness: 1.0 mm
- Nominal outer sheath thickness: 1.4 mm
A05VVR 4G16 #C
Nexans ref. 13001100 - Country ref. 13001100
- Packaging: Coil (m)
- Number of cores: 4
- Conductor cross-section: 16 mm²
- Phase Conductor Cross Section: 16 mm²
- Ground conductor cross-section: 16 mm²
- Nominal insulation thickness: 1.0 mm
- Nominal outer sheath thickness: 1.4 mm
A05VVR 4G16 #D
Nexans ref. 13001153 - Country ref. 13001153
- Packaging: Cut to length (m)
- Number of cores: 4
- Conductor cross-section: 16 mm²
- Phase Conductor Cross Section: 16 mm²
- Ground conductor cross-section: 16 mm²
- Nominal insulation thickness: 1.0 mm
- Nominal outer sheath thickness: 1.4 mm
A05VVR 4G16 #D
Nexans ref. 13000678 - Country ref. 13000678
- Packaging: Coil (m)
- Number of cores: 4
- Conductor cross-section: 16 mm²
- Phase Conductor Cross Section: 16 mm²
- Ground conductor cross-section: 16 mm²
- Nominal insulation thickness: 1.0 mm
- Nominal outer sheath thickness: 1.4 mm
A05VVR 5G 6 #C
Nexans ref. 13002925 - Country ref. 13002925
- Packaging: Coil (m)
- Number of cores: 5
- Conductor cross-section: 6 mm²
- Phase Conductor Cross Section: 6 mm²
- Ground conductor cross-section: 6 mm²
- Nominal insulation thickness: 0.8 mm
- Nominal outer sheath thickness: 1.4 mm
A05VVR 5G 6 #C/SL
Nexans ref. 13004970 - Country ref. 13004970
- Packaging: Coil (m)
- Number of cores: 5
- Conductor cross-section: 6 mm²
- Phase Conductor Cross Section: 6 mm²
- Ground conductor cross-section: 6 mm²
- Nominal insulation thickness: 0.8 mm
- Nominal outer sheath thickness: 1.4 mm
A05VVR 5G 6 #D
Nexans ref. 13002926 - Country ref. 13002926
- Packaging: Coil (m)
- Number of cores: 5
- Conductor cross-section: 6 mm²
- Phase Conductor Cross Section: 6 mm²
- Ground conductor cross-section: 6 mm²
- Nominal insulation thickness: 0.8 mm
- Nominal outer sheath thickness: 1.4 mm
A05VVR 5G10 #C
Nexans ref. 13001101 - Country ref. 13001101
- Packaging: Coil (m)
- Number of cores: 5
- Conductor cross-section: 10 mm²
- Phase Conductor Cross Section: 10 mm²
- Ground conductor cross-section: 10 mm²
- Nominal insulation thickness: 1.0 mm
- Nominal outer sheath thickness: 1.4 mm
A05VVR 5G10 #D
Nexans ref. 13001154 - Country ref. 13001154
- Packaging: Cut to length (m)
- Number of cores: 5
- Conductor cross-section: 10 mm²
- Phase Conductor Cross Section: 10 mm²
- Ground conductor cross-section: 10 mm²
- Nominal insulation thickness: 1.0 mm
- Nominal outer sheath thickness: 1.4 mm
A05VVR 5G10 #D
Nexans ref. 13000010 - Country ref. 13000010
- Packaging: Coil (m)
- Number of cores: 5
- Conductor cross-section: 10 mm²
- Phase Conductor Cross Section: 10 mm²
- Ground conductor cross-section: 10 mm²
- Nominal insulation thickness: 1.0 mm
- Nominal outer sheath thickness: 1.4 mm
A05VVR 5G10+1.5 #C
Nexans ref. 13001102 - Country ref. 13001102
- Packaging: Coil (m)
- Number of cores: 5
- Conductor cross-section: 10 mm²
- Phase Conductor Cross Section: 10 mm²
- Ground conductor cross-section: 10 mm²
- Nominal insulation thickness: 1.0 mm
- Nominal outer sheath thickness: 1.4 mm
A05VVR 5G10+1.5 #D
Nexans ref. 13001155 - Country ref. 13001155
- Packaging: Cut to length (m)
- Number of cores: 5
- Conductor cross-section: 10 mm²
- Phase Conductor Cross Section: 10 mm²
- Ground conductor cross-section: 10 mm²
- Nominal insulation thickness: 1.0 mm
- Nominal outer sheath thickness: 1.4 mm
A05VVR 5G10+1.5 #D
Nexans ref. 13000011 - Country ref. 13000011
- Packaging: Coil (m)
- Number of cores: 5
- Conductor cross-section: 10 mm²
- Phase Conductor Cross Section: 10 mm²
- Ground conductor cross-section: 10 mm²
- Nominal insulation thickness: 1.0 mm
- Nominal outer sheath thickness: 1.4 mm
A05VVU 2X 1.5 #C
Nexans ref. 13001158 - Country ref. 13001158
- Packaging: Coil (m)
- Number of cores: 2
- Conductor cross-section: 1.5 mm²
- Phase Conductor Cross Section: 1.5 mm²
- Ground conductor cross-section: - mm²
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.2 mm
A05VVU 2X 1.5 #C
Nexans ref. 13000014 - Country ref. 13000014
- Packaging: Coil (m)
- Number of cores: 2
- Conductor cross-section: 1.5 mm²
- Phase Conductor Cross Section: 1.5 mm²
- Ground conductor cross-section: - mm²
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.2 mm
A05VVU 2X 1.5 #D
Nexans ref. 13001105 - Country ref. 13001105
- Packaging: Cut to length (m)
- Number of cores: 2
- Conductor cross-section: 1.5 mm²
- Phase Conductor Cross Section: 1.5 mm²
- Ground conductor cross-section: - mm²
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.2 mm
A05VVU 2X 2.5 #C
Nexans ref. 13001159 - Country ref. 13001159
- Packaging: Coil (m)
- Number of cores: 2
- Conductor cross-section: 2.5 mm²
- Phase Conductor Cross Section: 2.5 mm²
- Ground conductor cross-section: - mm²
- Nominal insulation thickness: 0.8 mm
- Nominal outer sheath thickness: 1.2 mm
A05VVU 2X 2.5 #C
Nexans ref. 13000015 - Country ref. 13000015
- Packaging: Coil (m)
- Number of cores: 2
- Conductor cross-section: 2.5 mm²
- Phase Conductor Cross Section: 2.5 mm²
- Ground conductor cross-section: - mm²
- Nominal insulation thickness: 0.8 mm
- Nominal outer sheath thickness: 1.2 mm
A05VVU 2X 2.5 #D
Nexans ref. 13001106 - Country ref. 13001106
- Packaging: Cut to length (m)
- Number of cores: 2
- Conductor cross-section: 2.5 mm²
- Phase Conductor Cross Section: 2.5 mm²
- Ground conductor cross-section: - mm²
- Nominal insulation thickness: 0.8 mm
- Nominal outer sheath thickness: 1.2 mm
A05VVU 2X 2.5 #D
Nexans ref. 13001697 - Country ref. 13001697
- Packaging: Coil (m)
- Number of cores: 2
- Conductor cross-section: 2.5 mm²
- Phase Conductor Cross Section: 2.5 mm²
- Ground conductor cross-section: - mm²
- Nominal insulation thickness: 0.8 mm
- Nominal outer sheath thickness: 1.2 mm
A05VVU 2X 4 #C
Nexans ref. 13001160 - Country ref. 13001160
- Packaging: Coil (m)
- Number of cores: 2
- Conductor cross-section: 4 mm²
- Phase Conductor Cross Section: 4 mm²
- Ground conductor cross-section: - mm²
- Nominal insulation thickness: 0.8 mm
- Nominal outer sheath thickness: 1.2 mm
A05VVU 2X 4 #C
Nexans ref. 13000673 - Country ref. 13000673
- Packaging: Coil (m)
- Number of cores: 2
- Conductor cross-section: 4 mm²
- Phase Conductor Cross Section: 4 mm²
- Ground conductor cross-section: - mm²
- Nominal insulation thickness: 0.8 mm
- Nominal outer sheath thickness: 1.2 mm
A05VVU 2X 6 #C
Nexans ref. 13001161 - Country ref. 13001161
- Packaging: Coil (m)
- Number of cores: 2
- Conductor cross-section: 6 mm²
- Phase Conductor Cross Section: 6 mm²
- Ground conductor cross-section: - mm²
- Nominal insulation thickness: 0.8 mm
- Nominal outer sheath thickness: 1.2 mm
A05VVU 2X 6 #C
Nexans ref. 13000674 - Country ref. 13000674
- Packaging: Coil (m)
- Number of cores: 2
- Conductor cross-section: 6 mm²
- Phase Conductor Cross Section: 6 mm²
- Ground conductor cross-section: - mm²
- Nominal insulation thickness: 0.8 mm
- Nominal outer sheath thickness: 1.2 mm
A05VVU 3G 1.5 #C
Nexans ref. 13001164 - Country ref. 13001164
- Packaging: Coil (m)
- Number of cores: 3
- Conductor cross-section: 1.5 mm²
- Phase Conductor Cross Section: 1.5 mm²
- Ground conductor cross-section: 1.5 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.2 mm
A05VVU 3G 1.5 #C
Nexans ref. 13000016 - Country ref. 13000016
- Packaging: Coil (m)
- Number of cores: 3
- Conductor cross-section: 1.5 mm²
- Phase Conductor Cross Section: 1.5 mm²
- Ground conductor cross-section: 1.5 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.2 mm
A05VVU 3G 1.5 #C/SL
Nexans ref. 13004933 - Country ref. 13004933
- Packaging: Coil (m)
- Number of cores: 3
- Conductor cross-section: 1.5 mm²
- Phase Conductor Cross Section: 1.5 mm²
- Ground conductor cross-section: 1.5 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.2 mm
A05VVU 3G 1.5 #D
Nexans ref. 13001107 - Country ref. 13001107
- Packaging: Cut to length (m)
- Number of cores: 3
- Conductor cross-section: 1.5 mm²
- Phase Conductor Cross Section: 1.5 mm²
- Ground conductor cross-section: 1.5 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.2 mm
A05VVU 3G 2.5 #C
Nexans ref. 13001165 - Country ref. 13001165
- Packaging: Coil (m)
- Number of cores: 3
- Conductor cross-section: 2.5 mm²
- Phase Conductor Cross Section: 2.5 mm²
- Ground conductor cross-section: 2.5 mm²
- Nominal insulation thickness: 0.8 mm
- Nominal outer sheath thickness: 1.2 mm
A05VVU 3G 2.5 #C
Nexans ref. 13000017 - Country ref. 13000017
- Packaging: Coil (m)
- Number of cores: 3
- Conductor cross-section: 2.5 mm²
- Phase Conductor Cross Section: 2.5 mm²
- Ground conductor cross-section: 2.5 mm²
- Nominal insulation thickness: 0.8 mm
- Nominal outer sheath thickness: 1.2 mm
A05VVU 3G 2.5 #C/SL
Nexans ref. 13005007 - Country ref. 13005007
- Packaging: Coil (m)
- Number of cores: 3
- Conductor cross-section: 2.5 mm²
- Phase Conductor Cross Section: 2.5 mm²
- Ground conductor cross-section: 2.5 mm²
- Nominal insulation thickness: 0.8 mm
- Nominal outer sheath thickness: 1.2 mm
A05VVU 3G 2.5 #D
Nexans ref. 13001108 - Country ref. 13001108
- Packaging: Cut to length (m)
- Number of cores: 3
- Conductor cross-section: 2.5 mm²
- Phase Conductor Cross Section: 2.5 mm²
- Ground conductor cross-section: 2.5 mm²
- Nominal insulation thickness: 0.8 mm
- Nominal outer sheath thickness: 1.2 mm
A05VVU 3G 2.5 #D #1
Nexans ref. 13004540 - Country ref. 13004540
- Packaging: Coil (m)
- Number of cores: 3
- Conductor cross-section: 2.5 mm²
- Phase Conductor Cross Section: 2.5 mm²
- Ground conductor cross-section: 2.5 mm²
- Nominal insulation thickness: 0.8 mm
- Nominal outer sheath thickness: 1.2 mm
A05VVU 3G 4 #C
Nexans ref. 13001166 - Country ref. 13001166
- Packaging: Coil (m)
- Number of cores: 3
- Conductor cross-section: 4 mm²
- Phase Conductor Cross Section: 4 mm²
- Ground conductor cross-section: 4 mm²
- Nominal insulation thickness: 0.8 mm
- Nominal outer sheath thickness: 1.2 mm
A05VVU 3G 4 #C
Nexans ref. 13000018 - Country ref. 13000018
- Packaging: Coil (m)
- Number of cores: 3
- Conductor cross-section: 4 mm²
- Phase Conductor Cross Section: 4 mm²
- Ground conductor cross-section: 4 mm²
- Nominal insulation thickness: 0.8 mm
- Nominal outer sheath thickness: 1.2 mm
A05VVU 3G 4 #C/SL
Nexans ref. 13004973 - Country ref. 13004973
- Packaging: Coil (m)
- Number of cores: 3
- Conductor cross-section: 4 mm²
- Phase Conductor Cross Section: 4 mm²
- Ground conductor cross-section: 4 mm²
- Nominal insulation thickness: 0.8 mm
- Nominal outer sheath thickness: 1.2 mm
A05VVU 3G 4 #D
Nexans ref. 13001109 - Country ref. 13001109
- Packaging: Cut to length (m)
- Number of cores: 3
- Conductor cross-section: 4 mm²
- Phase Conductor Cross Section: 4 mm²
- Ground conductor cross-section: 4 mm²
- Nominal insulation thickness: 0.8 mm
- Nominal outer sheath thickness: 1.2 mm
A05VVU 3G 6 #C
Nexans ref. 13001167 - Country ref. 13001167
- Packaging: Coil (m)
- Number of cores: 3
- Conductor cross-section: 6 mm²
- Phase Conductor Cross Section: 6 mm²
- Ground conductor cross-section: 6 mm²
- Nominal insulation thickness: 0.8 mm
- Nominal outer sheath thickness: 1.4 mm
A05VVU 3G 6 #C
Nexans ref. 13000019 - Country ref. 13000019
- Packaging: Coil (m)
- Number of cores: 3
- Conductor cross-section: 6 mm²
- Phase Conductor Cross Section: 6 mm²
- Ground conductor cross-section: 6 mm²
- Nominal insulation thickness: 0.8 mm
- Nominal outer sheath thickness: 1.4 mm
A05VVU 3G 6 #D
Nexans ref. 13001110 - Country ref. 13001110
- Packaging: Cut to length (m)
- Number of cores: 3
- Conductor cross-section: 6 mm²
- Phase Conductor Cross Section: 6 mm²
- Ground conductor cross-section: 6 mm²
- Nominal insulation thickness: 0.8 mm
- Nominal outer sheath thickness: 1.4 mm
A05VVU 4G 1.5 #C
Nexans ref. 13001168 - Country ref. 13001168
- Packaging: Coil (m)
- Number of cores: 4
- Conductor cross-section: 1.5 mm²
- Phase Conductor Cross Section: 1.5 mm²
- Ground conductor cross-section: 1.5 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.2 mm
A05VVU 4G 1.5 #C
Nexans ref. 13000020 - Country ref. 13000020
- Packaging: Coil (m)
- Number of cores: 4
- Conductor cross-section: 1.5 mm²
- Phase Conductor Cross Section: 1.5 mm²
- Ground conductor cross-section: 1.5 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.2 mm
A05VVU 4G 1.5 #C/SL
Nexans ref. 13004974 - Country ref. 13004974
- Packaging: Coil (m)
- Number of cores: 4
- Conductor cross-section: 1.5 mm²
- Phase Conductor Cross Section: 1.5 mm²
- Ground conductor cross-section: 1.5 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.2 mm
A05VVU 4G 1.5 #D
Nexans ref. 13001111 - Country ref. 13001111
- Packaging: Cut to length (m)
- Number of cores: 4
- Conductor cross-section: 1.5 mm²
- Phase Conductor Cross Section: 1.5 mm²
- Ground conductor cross-section: 1.5 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.2 mm
A05VVU 4G 2.5 #C
Nexans ref. 13001169 - Country ref. 13001169
- Packaging: Coil (m)
- Number of cores: 4
- Conductor cross-section: 2.5 mm²
- Phase Conductor Cross Section: 2.5 mm²
- Ground conductor cross-section: 2.5 mm²
- Nominal insulation thickness: 0.8 mm
- Nominal outer sheath thickness: 1.2 mm
A05VVU 4G 2.5 #C
Nexans ref. 13000021 - Country ref. 13000021
- Packaging: Coil (m)
- Number of cores: 4
- Conductor cross-section: 2.5 mm²
- Phase Conductor Cross Section: 2.5 mm²
- Ground conductor cross-section: 2.5 mm²
- Nominal insulation thickness: 0.8 mm
- Nominal outer sheath thickness: 1.2 mm
A05VVU 4G 2.5 #D
Nexans ref. 13001112 - Country ref. 13001112
- Packaging: Cut to length (m)
- Number of cores: 4
- Conductor cross-section: 2.5 mm²
- Phase Conductor Cross Section: 2.5 mm²
- Ground conductor cross-section: 2.5 mm²
- Nominal insulation thickness: 0.8 mm
- Nominal outer sheath thickness: 1.2 mm
A05VVU 4G 4 #C
Nexans ref. 13001170 - Country ref. 13001170
- Packaging: Coil (m)
- Number of cores: 4
- Conductor cross-section: 4 mm²
- Phase Conductor Cross Section: 4 mm²
- Ground conductor cross-section: 4 mm²
- Nominal insulation thickness: 0.8 mm
- Nominal outer sheath thickness: 1.2 mm
A05VVU 4G 4 #C
Nexans ref. 13000022 - Country ref. 13000022
- Packaging: Coil (m)
- Number of cores: 4
- Conductor cross-section: 4 mm²
- Phase Conductor Cross Section: 4 mm²
- Ground conductor cross-section: 4 mm²
- Nominal insulation thickness: 0.8 mm
- Nominal outer sheath thickness: 1.2 mm
A05VVU 4G 4 #D
Nexans ref. 13001113 - Country ref. 13001113
- Packaging: Cut to length (m)
- Number of cores: 4
- Conductor cross-section: 4 mm²
- Phase Conductor Cross Section: 4 mm²
- Ground conductor cross-section: 4 mm²
- Nominal insulation thickness: 0.8 mm
- Nominal outer sheath thickness: 1.2 mm
A05VVU 4G 4 #D
Nexans ref. 13001728 - Country ref. 13001728
- Packaging: Coil (m)
- Number of cores: 4
- Conductor cross-section: 4 mm²
- Phase Conductor Cross Section: 4 mm²
- Ground conductor cross-section: 4 mm²
- Nominal insulation thickness: 0.8 mm
- Nominal outer sheath thickness: 1.2 mm
A05VVU 4G 6 #C
Nexans ref. 13001171 - Country ref. 13001171
- Packaging: Coil (m)
- Number of cores: 4
- Conductor cross-section: 6 mm²
- Phase Conductor Cross Section: 6 mm²
- Ground conductor cross-section: 6 mm²
- Nominal insulation thickness: 0.8 mm
- Nominal outer sheath thickness: 1.4 mm
A05VVU 4G 6 #C
Nexans ref. 13000023 - Country ref. 13000023
- Packaging: Coil (m)
- Number of cores: 4
- Conductor cross-section: 6 mm²
- Phase Conductor Cross Section: 6 mm²
- Ground conductor cross-section: 6 mm²
- Nominal insulation thickness: 0.8 mm
- Nominal outer sheath thickness: 1.4 mm
A05VVU 4G 6 #D
Nexans ref. 13001114 - Country ref. 13001114
- Packaging: Cut to length (m)
- Number of cores: 4
- Conductor cross-section: 6 mm²
- Phase Conductor Cross Section: 6 mm²
- Ground conductor cross-section: 6 mm²
- Nominal insulation thickness: 0.8 mm
- Nominal outer sheath thickness: 1.4 mm
A05VVU 5G 1.5 #C
Nexans ref. 13001172 - Country ref. 13001172
- Packaging: Coil (m)
- Number of cores: 5
- Conductor cross-section: 1.5 mm²
- Phase Conductor Cross Section: 1.5 mm²
- Ground conductor cross-section: 1.5 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.2 mm
A05VVU 5G 1.5 #C
Nexans ref. 13000024 - Country ref. 13000024
- Packaging: Coil (m)
- Number of cores: 5
- Conductor cross-section: 1.5 mm²
- Phase Conductor Cross Section: 1.5 mm²
- Ground conductor cross-section: 1.5 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.2 mm
A05VVU 5G 1.5 #D
Nexans ref. 13001115 - Country ref. 13001115
- Packaging: Cut to length (m)
- Number of cores: 5
- Conductor cross-section: 1.5 mm²
- Phase Conductor Cross Section: 1.5 mm²
- Ground conductor cross-section: 1.5 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.2 mm
A05VVU 5G 2.5 #C
Nexans ref. 13001173 - Country ref. 13001173
- Packaging: Coil (m)
- Number of cores: 5
- Conductor cross-section: 2.5 mm²
- Phase Conductor Cross Section: 2.5 mm²
- Ground conductor cross-section: 2.5 mm²
- Nominal insulation thickness: 0.8 mm
- Nominal outer sheath thickness: 1.2 mm
A05VVU 5G 2.5 #C
Nexans ref. 13000025 - Country ref. 13000025
- Packaging: Coil (m)
- Number of cores: 5
- Conductor cross-section: 2.5 mm²
- Phase Conductor Cross Section: 2.5 mm²
- Ground conductor cross-section: 2.5 mm²
- Nominal insulation thickness: 0.8 mm
- Nominal outer sheath thickness: 1.2 mm
A05VVU 5G 2.5 #C/SL
Nexans ref. 13004961 - Country ref. 13004961
- Packaging: Coil (m)
- Number of cores: 5
- Conductor cross-section: 2.5 mm²
- Phase Conductor Cross Section: 2.5 mm²
- Ground conductor cross-section: 2.5 mm²
- Nominal insulation thickness: 0.8 mm
- Nominal outer sheath thickness: 1.2 mm
A05VVU 5G 2.5 #D
Nexans ref. 13001116 - Country ref. 13001116
- Packaging: Cut to length (m)
- Number of cores: 5
- Conductor cross-section: 2.5 mm²
- Phase Conductor Cross Section: 2.5 mm²
- Ground conductor cross-section: 2.5 mm²
- Nominal insulation thickness: 0.8 mm
- Nominal outer sheath thickness: 1.2 mm
A05VVU 5G 2.5 #D #1
Nexans ref. 13004541 - Country ref. 13004541
- Packaging: Coil (m)
- Number of cores: 5
- Conductor cross-section: 2.5 mm²
- Phase Conductor Cross Section: 2.5 mm²
- Ground conductor cross-section: 2.5 mm²
- Nominal insulation thickness: 0.8 mm
- Nominal outer sheath thickness: 1.2 mm
A05VVU 5G 4 #C
Nexans ref. 13001174 - Country ref. 13001174
- Packaging: Coil (m)
- Number of cores: 5
- Conductor cross-section: 4 mm²
- Phase Conductor Cross Section: 4 mm²
- Ground conductor cross-section: 4 mm²
- Nominal insulation thickness: 0.8 mm
- Nominal outer sheath thickness: 1.4 mm
A05VVU 5G 4 #C
Nexans ref. 13000026 - Country ref. 13000026
- Packaging: Coil (m)
- Number of cores: 5
- Conductor cross-section: 4 mm²
- Phase Conductor Cross Section: 4 mm²
- Ground conductor cross-section: 4 mm²
- Nominal insulation thickness: 0.8 mm
- Nominal outer sheath thickness: 1.4 mm
A05VVU 5G 4 #C/SL
Nexans ref. 13005005 - Country ref. 13005005
- Packaging: Coil (m)
- Number of cores: 5
- Conductor cross-section: 4 mm²
- Phase Conductor Cross Section: 4 mm²
- Ground conductor cross-section: 4 mm²
- Nominal insulation thickness: 0.8 mm
- Nominal outer sheath thickness: 1.4 mm
A05VVU 5G 4 #D
Nexans ref. 13001117 - Country ref. 13001117
- Packaging: Cut to length (m)
- Number of cores: 5
- Conductor cross-section: 4 mm²
- Phase Conductor Cross Section: 4 mm²
- Ground conductor cross-section: 4 mm²
- Nominal insulation thickness: 0.8 mm
- Nominal outer sheath thickness: 1.4 mm
A05VVU 5G 6 #C
Nexans ref. 13001175 - Country ref. 13001175
- Packaging: Coil (m)
- Number of cores: 5
- Conductor cross-section: 6 mm²
- Phase Conductor Cross Section: 6 mm²
- Ground conductor cross-section: 6 mm²
- Nominal insulation thickness: 0.8 mm
- Nominal outer sheath thickness: 1.4 mm
A05VVU 5G 6 #C
Nexans ref. 13000027 - Country ref. 13000027
- Packaging: Coil (m)
- Number of cores: 5
- Conductor cross-section: 6 mm²
- Phase Conductor Cross Section: 6 mm²
- Ground conductor cross-section: 6 mm²
- Nominal insulation thickness: 0.8 mm
- Nominal outer sheath thickness: 1.4 mm
A05VVU 5G 6 #D
Nexans ref. 13001118 - Country ref. 13001118
- Packaging: Cut to length (m)
- Number of cores: 5
- Conductor cross-section: 6 mm²
- Phase Conductor Cross Section: 6 mm²
- Ground conductor cross-section: 6 mm²
- Nominal insulation thickness: 0.8 mm
- Nominal outer sheath thickness: 1.4 mm
Description
Description
Standards
-
InternationalHD 21.4; IEC 60332-1
-
NationalELOT 563.4
Copper cable with solid or stranded copper conductor suitable for installation in dry or wet places.
Design
- Copper conductor
- PVC Insulation
- PVC Outer sheath
Core marking
2-cores: Brown, Blue
3-cores: Brown, Yellow-green, Blue
4-cores: Brwon, Black, Grey, Yellow-green
5-cores: Brown, Black, Grey, Yellow-green, Blue
Cable construction
1. copper conductor
2. PVC insulation
3. PVC outer sheath
Note: upon request the cable could be manufactured with higher fire retardant performance to meet the standards BS/EN 50266 cat C, IEC 60332-3-24 cat C
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Resources
Resources
Selling & delivery Information
Note: U: solid conductor, R: round stranded conductor
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania