- Company
- Markets
- 
					        Products
					        - Products
- Building cables
- Outdoor/Industrial Non Armored Cables
- Outdoor/Industrial Armored Cables
- Earth Conductors
- Solar farms
- Safety Cables
- Power Distribution Aerial cables
- Power Transmission & Distribution Conductors OHL
- Power Distribution cables
- 
				                    MV Underground Armored cables
									- Overview
- CU/XLPE/CTS/LSF/AWA/LSF 6.35/11KV
- CU/XLPE/CTS/PVC/SWA/PVC 12.7/22KV RED STRIPE
- CU/XLPE/CTS/PVC/AWA/PVC 6.35/11KV
- CU/XLPE/CTS/PVC/SWA/PVC 6.35/11KV
- CU/XLPE/CTS/LSF/SWA/LSF 6.35/11 KV
- CU/XLPE/CTS/PVC/SWA/PVC 19/33KV RED STRIPE
- CU/XLPE/CTS/PVC/AWA/PVC 19/33KV
- CU/XLPE/CTS/PVC/AWA/PVC 12.7/22KV RED STRIPE
- CU/XLPE/CTS/PVC/SWA/PVC 6.35/11KV RED STRIPE
- CU/XLPE/CTS/PVC/AWA/PVC 6.35/11KV RED STRIPE
- CU/XLPE/CTS/PVC/AWA/PVC 19/33 KV RED STRIPE
 
- 
				                    MV Underground Unarmored cables
									- Overview
- NA2XS(F)2Y RM 6/10 KV
- CU/XLPE/CWS/PE 6.35/11KV - BS 7870-4.10
- A2XS(F)2Y 12/20KV - IEC
- NA2XS(F)2Y RM 18/30 kV
- AL/XLPE/CWS/PVC 12/20KV - DEH
- NA2XS(F)2Y RM 12/20 kV
- CU/XLPE/CWS/PE 6.35/11KV - TRIPLEX - BS 7870-4.10
- 2XSY 12/20 KV - IEC
- AL/XLPE/CWS/PE 6.35/11KV - TRIPLEX - BS 7870-4.10
- AL/XLPE/PVC 12/20KV - triplex - Underground - DEH
- A2XSY 12/20KV - IEC
- CU/XLPE/CWS/PVC 12/20KV 3-CORE -IEC
- AL/XLPE/AWS/PE 6.35/11KV - TRIPLEX - IEC
- AL/XLPE/CWS/WB/PE 19/33KV - BS 7870-4.10
- AL/XLPE/CWS/PE 19/33KV - BS 7870-4.10
- AL/XLPE/AWS/WB/PE 19/33KV
- AL/XLPE/CWS/PE/SC 19/33KV - BS 7870-4.10
- A2XSH 12/20KV - DEH
- AXCLIGHT TT 12kV
- AXCLIGHT TT E 36kV
- NA2XS(FL)2Y V RM 12/20 kV
- AXCLIGHT TT 24kV
- CU/XLPE/AWS/PE 6.35/11KV - TRIPLEX - IEC
- AL/XLPE/AL-PE/PE 12/20KV 3.0 - IEC
- NA2XS(F)2Y RM 12/20 kV - triplex
- AL/XLPE/CWS/PE 6.35/11KV - BS 7870-4.20
- NA2XS(F)2Y V RM 12/20 kV
- AXLJ TT 36 kV
- CU/XLPE/AWS/LSF 6.35/11KV - IEC
- NA2XS2Y RM 6/10 KV - Triplex
 
 
- Newsroom
- Tools & Resources
- Newsletter
- Search
- Contact us
- Compare
- Sign in
CEANDER 4X 95AL+59CU SE #D #N #1
CEANDER 4X 95AL+59CU SE #D #N #1
CEANDER 4X 95AL+59CU SE #D #N #1
Read more- Nexans ref. : 13005668
- Country ref. : 13005668
- EAN : 5204609063274
Description
Description
Standards
- 
                                            ProductBS 7870-3.40; IEC 60502-1
- 
                                            TestIEC 60332-1-2
Application
Power cable for outdoor applications. The cable is suitable for direct buried installation in ground and cable ducts. For single branch joints (T-joints) in local networks the concentric conductor can be connected uncut.
According to CPR regulation the cable is Euroclass Eca
Construction
The cable is consisted of Aluminium sector shapped solid conductors with XLPE insulation, extruded inner covering, waveform conductor of copper wires, PVC outer sheath.
The colors of XLPE insulation are:
- 3-core: brown, black, grey
- 4-core: brown, black, grey, blue
Characteristics
Characteristics
Construction characteristics
Construction characteristics
                                                                Conductor material
                                                            
                                                            
                                                                Aluminum 
                                                            
                                                        
                                                                Conductor shape
                                                            
                                                            
                                                                Sector-shaped 
                                                            
                                                        
                                                                Conductor flexibility
                                                            
                                                            
                                                                Solid class 1 
                                                            
                                                        
                                                                Insulation
                                                            
                                                            
                                                                XLPE 
                                                            
                                                        
                                                                Concentric conductor
                                                            
                                                            
                                                                Bare copper wires 
                                                            
                                                        
                                                                Outer sheath
                                                            
                                                            
                                                                PVC 
                                                            
                                                        
                                                                Sheath colour
                                                            
                                                            
                                                                Black 
                                                            
                                                        
                                                                Lead free
                                                            
                                                            
                                                                Yes 
                                                            
                                                        
                                                                With Green/Yellow core
                                                            
                                                            
                                                                No 
                                                            
                                                        
                                                                With smaller neutral conductor
                                                            
                                                            
                                                                No 
                                                            
                                                        Dimensional characteristics
Dimensional characteristics
                                                                Number of cores
                                                            
                                                            
                                                                4 
                                                            
                                                        
                                                                Conductor cross-section
                                                            
                                                            
                                                                95 mm²
                                                            
                                                        
                                                                Phase Conductor Cross Section
                                                            
                                                            
                                                                95 mm²
                                                            
                                                        
                                                                Nominal insulation thickness
                                                            
                                                            
                                                                1.1 mm
                                                            
                                                        
                                                                Nominal outer sheath thickness
                                                            
                                                            
                                                                2.2 mm
                                                            
                                                        
                                                                Nominal outer diameter
                                                            
                                                            
                                                                39.0 mm
                                                            
                                                        
                                                                Approximate weight
                                                            
                                                            
                                                                2365 kg/km
                                                            
                                                        
                                                                Neutral conductor section (when smaller)
                                                            
                                                            
                                                                - mm²
                                                            
                                                        Electrical characteristics
Electrical characteristics
                                                                Rated Voltage Uo/U (Um)
                                                            
                                                            
                                                                0,6/1 kV 
                                                            
                                                        
                                                                Max. DC resistance of the conductor at 20°C
                                                            
                                                            
                                                                0.32 Ohm/km
                                                            
                                                        
                                                                Permissible current rating when buried
                                                            
                                                            
                                                                244 A
                                                            
                                                        Resources
Resources
Current capacity table XLPE insulation multicore single phase
XLPE or EPR insulation, two loaded conductors/copper or aluminium Conductor temperature: 90 °C, ambient temperature: 30 °C in air, 20 °C in ground| Conductor cross-section | A2 Multi-core cable in conduit in a thermally insulated wall | B2 Multi-core cable in conduit on a wooden wall | C Single-core or multi-core cable on a wooden wall | D1 Single-core or Multi-core cable in ducts in the ground | D2 Single-core or Multi-core cables designed to be buried directly in the ground | E Multi-core cable in free air | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| mm² | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | 
| 95.0 | 220.0 | 175.0 | 265.0 | 210.0 | 328.0 | 241.0 | 239.0 | 186.0 | 270.0 | 204.0 | 352.0 | 257.0 | 
Current capacity table XLPE insulation multicore three phase
XLPE or EPR insulation, three loaded conductors/copper or aluminium – Conductor temperature: 90 °C, ambient temperature: 30 °C in air, 20 °C in ground| Conductor cross-section | A2 Multi-core cable in conduit in a thermally insulated wall | B2 Multi-core cable in conduit on a wooden wall | C Single-core or multi-core cable on a wooden wall | D1 Single-core or Multi-core cable in ducts in the ground | D2 Single-core or Multi-core cables designed to be buried directly in the ground | E Multi-core cable in free air | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| mm² | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | 
| 95.0 | 197.0 | 157.0 | 233.0 | 188.0 | 278.0 | 211.0 | 197.0 | 154.0 | 226.0 | 172.0 | 298.0 | 227.0 | 
Declaration of Performance
- Declaration of Performance n� : 1000703-GRLA
- Certification Date : 4/18/18
- AVCP (Assessment and Verification of Constancy of Performance) : System 3
- Notified body : 0832
- Declared performance : Eca
Our websites
Select your country to find our products and solutions
- 
                        Africa
                        
                        
                        - Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
 
- Americas
- Asia
- Europe
- Oceania